EOG Monitoring System (EOM-3000)

Newly released "EOG Monitoring System (EOM-3000)" for measuring EO concentration in EOG sterilizers with simple operation.

【Main Features】 1. Easy operation allows for the measurement of EO gas concentration and EO residue concentration within the EO sterilizer. 2. Measurement of EO concentration can be performed in both continuous automatic (monitoring mode) and manual (measurement instruction mode) settings. 3. By measuring EO concentration, safe and efficient (cost-effective) sterilization operations can be conducted. 4. Real-time monitoring and evaluation of EOG sterilization, measurement of residual EO concentration and safety evaluation, and record management via external output are possible. 5. This is an EO gas analysis device specialized for measuring EO concentration. 【Main Effects】 1. Compliance with the Ministry of Health, Labour and Welfare's requirement for recording ethylene oxide (EO) sterilization conditions. 2. Ability to respond to inspections by the US FDA (Food and Drug Administration) regarding export approvals for medical devices intended for the US market. 3. Compliance with ISO requirements for measuring residual EO concentration and recording obligations for ethylene oxide (EO) sterilization conditions. 4. Ability to provide detailed reports to clients such as sterilization contractors. For inquiries regarding this matter: 2-2-8 Minami Tsutsujigaoka, Kameoka City, Kyoto Prefecture, 621-0847 Space Works Contact: Wada wadakame@siren.ocn.ne.jp

  • Cooking facility equipment and supplies
  • Ski related facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EOG Monitoring System (EOM-5000/S)

Launched the "EOG Monitoring System (EOM-5000/S)" that can continuously and automatically measure the EO concentration of multiple EOG sterilizers.

1. Continuous automatic measurement of the EO concentration in multiple EOG sterilizers can be performed, allowing for recording and measurement of EO residual concentration. 2. It can accommodate six EOG sterilizers, allowing for the selection of any number of units and prioritization as desired. 3. Objective monitoring and evaluation of EOG sterilization, rapid measurement and safety evaluation of residual EO concentration, as well as management of these records can be performed. 4. Management of sterilization and safety can be easily conducted, enabling safe and efficient (cost-effective) sterilization operations. 【Main Effects】 (A) Compliance with the Ministry of Health, Labour and Welfare's obligation to record ethylene oxide (EO) sterilization conditions. (B) Compliance with inspections by the U.S. FDA (Food and Drug Administration) regarding export approvals for medical devices intended for the U.S. market. (C) Compliance with ISO requirements for measuring residual EO concentration and recording obligations for ethylene oxide (EO) sterilization conditions. (D) Compliance with reporting details to clients such as contract sterilization service providers. (E) Easy compliance with the above items (A) to (D). ■ Contact Information for Inquiries 2-2-8 Minami Tsutsujigaoka, Kameoka City, Kyoto Prefecture, 621-0847 Space Works Contact: Wada wadakame@siren.ocn.ne.jp TEL: 0771-25-3430 / FAX: 0771-25-4932

  • Cooking facility equipment and supplies
  • Ski related facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EOG Monitoring System (EOM-5000)

Released the "EOG Monitoring System (EOM-5000)" capable of concentration measurement in accordance with the sterilization process of EO gas sterilizers.

【Main Features】 1. Measurement of EO gas concentration and residual EO concentration in the EO sterilizer with simple operation. 2. Measurement of EO concentration in accordance with the sterilization process (measurement analysis). 3. Recording of EO concentration in accordance with the sterilization process, with date, time, and concentration printed by the recorder or printer. 4. Measurement of EO concentration can be performed in continuous automatic (monitoring mode) and manual (measurement instruction mode) modes. 5. Safe and efficient (cost-effective) sterilization operations can be conducted. 6. Objective monitoring and evaluation of EOG sterilization / measurement of residual EO concentration and safety evaluation / record management. 【Main Effects】 1. Compliance with the Ministry of Health, Labour and Welfare's obligation to record ethylene oxide (EO) sterilization conditions. 2. Compliance with U.S. FDA (Food and Drug Administration) inspections related to export approval for medical devices intended for the U.S. market. 3. Compliance with ISO requirements for measuring residual EO concentration and recording obligations for ethylene oxide (EO) sterilization conditions. 4. Compliance with reporting details for clients such as contract sterilization service providers. ■ Contact Information for Inquiries 2-2-8 Minami Tsutsuji-ga-oka, Kameoka City, Kyoto Prefecture, 621-0847 Space Works Contact: Wada wadakame@siren.ocn.ne.jp TEL: 0771-25-3430 / FAX: 0771-25-4932

  • Cooking facility equipment and supplies
  • Ski related facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration